Coolant Distribution Units

Coolant Distribution Unit AL-6

A 4U, 6kW air-to-liquid CDU with redundant variable-speed pumps and PLC-based monitoring.

Coolant Distribution Unit AL-6 — embodyne.ai

The AL-6 is a rack-mounted heat-exchange unit for ultra-high-density cold-plate liquid-cooled servers. Its rated cooling capacity is 6kW. Clamp connections simplify installation, while redundant pumps support reliable operation and maintenance. The system manages server cooling and cooling-capacity distribution, with comprehensive real-time parameter monitoring. Redundant RS485 and RJ45 communication interfaces use Modbus RTU and Modbus TCP/IP by default.

Selection and project planning

The AL-6 should be assessed against the actual coolant circuit and room environment, not chosen from its model name alone. Review published cooling capacity, flow, temperature conditions and connections alongside the server heat load. Account for the heat discharged into the room and the space needed for access and maintenance. Establish the power supply, monitoring requirements and site constraints before comparing it with larger liquid-to-air alternatives.

Key features

Intelligent flow control

Redundant pump motors use variable-speed control to adjust system flow in response to server load.

System monitoring

PLC control integrates monitoring of temperature, flow, pressure, leakage and liquid level.

Intelligent alarms

A three-level alarm mechanism helps operations staff locate system abnormalities quickly.

Specifications

Technical specifications
ParameterValue
Height4U
Dimensions177 × 481 × 982mm (H × W × D)
Rated cooling capacity6kW
Cooling mediumPrimary side: air; Secondary side: specialist coolant
FlowPrimary side: 500 m³/h; Secondary side: 0.36 m³/h
Maximum rated output differential pressureSecondary side: ≥1.0bar
Rated inlet temperaturePrimary side: 25°C; Secondary side: 54.8°C
Rated outlet temperaturePrimary side: 47°C; Secondary side: 40°C
Airflow directionFront intake, rear exhaust
Pump drive configurationDual-pump variable-frequency control
Maximum power consumption300W
Power specification2 × 1P 220V 50Hz/60Hz
External connections1″ clamp connections
Power connectors2 × C14
Communication interfaces2 × RS485 & 2 × RJ45
Communication protocolsModbus RTU & Modbus TCP/IP
Refill connectionUQD04 male connection
Noise level85dB(A)

Applications

  • Liquid-cooled data centres

Compare related models

These published details support comparison and system planning; links do not confirm compatibility. Review each model's complete specifications before configuration.

Contact our team for AL-6 availability and project requirements.

Request product information